中文EnglishDisclaimers|Sitemap|
1.jpg

Metal rotor flowmeter

Metal rotor flowmeter has the advantages of simple structure, reliable operation, wide application
  • Tel:15212180111
  • Fax
  • Email:micmenon@163.com
Description

Metal rotor flowmeter has the advantages of simple structure, reliable operation, wide application range, accurate measurement and easy installation. With high temperature resistance, high pressure resistance of metal rotor flowmeter has a common type and anti-corrosion type. The above two types are divided into field indicating metal rotor flowmeter (LZZ-) and electric remote transmission metal rotor flowmeter (LZD-), ordinary flow sensor, instrument material for (1Cr18Ni9Ti), anti-corrosion type for (1Cr18Ni9Ti) lining PTEF.

If the metal rotor meter measures a medium containing ferromagnetic particles, a magnetic filter should be installed at the entrance of the meter. Its material should be the same as the corresponding flowmeter.

Metal rotor flowmeter technical parameters

Measuring range: water (20℃) 1-200000 l/h

Air (20℃, 0.1013MPa) 0.03-4000m3/h

See flow meter, special flow can be customized

Range ratio: standard 10:1

Accuracy: Standard type 1.5 grade

Pressure grade: Standard type: DN15-DN50 4.0MPa, DN80-DN200 1.6MPa

Special type: DN15-DN50 25MPa DN80-DN200 16MPa

The pressure rating of the jacket is 1.6MPa

Special type should be consulted with the factory before selection and ordering

Pressure loss: 7kPa-70kPa

Medium temperature: standard type: -80℃-+200℃ : PTFE: 0℃-85℃

High temperature type: up to 400℃

Medium viscosity: DN15:<5mPa.s(F15.1-F15.3)

< 30 mpa s (F15.4 - F15.8)

DN25:<250mPFa.s

DN50-DN150:<300mPa.s

Ambient temperature: liquid crystal type -30℃-+85℃

Pointer type -40℃-+120℃

Connection form: Standard type: DIN2501 standard flange

Special type: Any standard flange or thread specified by the user

Cable interface: M20 * 1.5

Power supply: Standard 24VDC two-wire system 4-20mA (10.8Vd-36VDC)

Ac type: 85-265VAC 50HZ

Battery type: 3.6V@4AH NIMH battery

Alarm output: upper limit or lower limit instantaneous flow alarm

Standard type: open collector output (maximum 100mA@30VDC internal impedance 100 ohms)

Special type: relay output (maximum contact capacity 5A@250VAC)

Pulse output: Cumulative pulse output, minimum interval 50 ms

Liquid crystal display: instantaneous flow display value range: 0-50000

Cumulative traffic display value range: 0 to 99999999

Protection level: IP65

Explosion-proof mark: Intrinsic safety type iaⅡCT6 flameproof type dⅡCT6


Browse:
Return To The Top