中文EnglishDisclaimers|Sitemap|

Characteristics and installation precautions of rotor flowmeter

Rotameter has the characteristics of simple structure, reliable operation, wide application range, accurate measurement, easy installation, etc. It has high temperature resistance, high pressure resistance, ZY series metal tube rotameter has ordinary type and anti-corrosion type. The above two types are divided into field indicating type and electric remote transmission type, ordinary type flow sensor, instrument material for (1Cr18Ni9Ti), anti-corrosion type for (1Cr18Ni9Ti) lining PTEF.

Precautions for installation of rotor flowmeter

1: The flowmeter must be installed vertically, the measured flow body bottom-up through the flowmeter, the import and export are guaranteed to have 5 times the diameter of the meter straight pipe section, for the newly installed pipeline, the flowmeter should be cleaned before installation.

2: In order to facilitate maintenance and replacement of the flow meter, it is necessary to connect the side pipe when the instrument is installed.

3: In the upstream of the flow meter should be installed valve, in the downstream 5~10 times the diameter of the instrument installed flow control valve. For small diameter instruments, a filter should be installed upstream. If the measured medium contains magnetic substances, a magnetic filter should be installed in front of the flowmeter.

4: When the measured medium is dirty, the pipe and float should be cleaned in time.

5: The measurement accuracy of metal rotor flowmeter is generally 2.5, when the measurement accuracy is higher, it is not suitable to choose metal rotor flowmeter.


Browse: